The burners TriOx have been optimized for use in continuousfurnace systems. They can be switched to INVISIFLAME® mode forultra low NOX at a furnace temperature of > 870°C. Furthermore,variants which only operate in INVISIFLAME® mode are availablefor high-temperature applications. The burners are equipped with arefractory concrete combustion chamber. No additional burnerquarl is necessary. The burners are predominantly used in brick-lined furnaces.
Key attributes
Low air and fuel pressure requirements. Optimized to produce lowemissions levels. Insulated versions for preheated air up to 480°C(900°F).
FEATURES
- Type: Nozzle-mixing
- Number of sizes: 5
- Capacity range: 700 – 7310 kW
- Turndown: 10:1
- Max. process temperature: 1480 ℃
- Max. combustion air: TriOx 1:ambient temperature TriOx 2: 480 °C
- Fuels: Natural gas, propane, butane